Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Basic Res Cardiol ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536505

RESUMO

Right ventricular (RV) failure remains the strongest determinant of survival in pulmonary hypertension (PH). We aimed to identify relevant mechanisms, beyond pressure overload, associated with maladaptive RV hypertrophy in PH. To separate the effect of pressure overload from other potential mechanisms, we developed in pigs two experimental models of PH (M1, by pulmonary vein banding and M2, by aorto-pulmonary shunting) and compared them with a model of pure pressure overload (M3, pulmonary artery banding) and a sham-operated group. Animals were assessed at 1 and 8 months by right heart catheterization, cardiac magnetic resonance and blood sampling, and myocardial tissue was analyzed. Plasma unbiased proteomic and metabolomic data were compared among groups and integrated by an interaction network analysis. A total of 33 pigs completed follow-up (M1, n = 8; M2, n = 6; M3, n = 10; and M0, n = 9). M1 and M2 animals developed PH and reduced RV systolic function, whereas animals in M3 showed increased RV systolic pressure but maintained normal function. Significant plasma arginine and histidine deficiency and complement system activation were observed in both PH models (M1&M2), with additional alterations to taurine and purine pathways in M2. Changes in lipid metabolism were very remarkable, particularly the elevation of free fatty acids in M2. In the integrative analysis, arginine-histidine-purines deficiency, complement activation, and fatty acid accumulation were significantly associated with maladaptive RV hypertrophy. Our study integrating imaging and omics in large-animal experimental models demonstrates that, beyond pressure overload, metabolic alterations play a relevant role in RV dysfunction in PH.

2.
Can J Cardiol ; 40(2): 218-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37758014

RESUMO

The growing number of candidates for transcatheter aortic valve replacement (TAVR) has increased the interest in the concomitant presence of coronary artery disease (CAD) and severe aortic stenosis (AS), prompting the need to define the appropriate revascularization strategy for each case. The reported prevalence of concurrent AS and CAD has varied over the years on the basis of the CAD definition and the population evaluated. Revascularization for treating CAD in patients with severe AS involves additional interventions that could impact outcomes. The addition of coronary artery bypass grafting (CABG) to surgical aortic valve replacement (SAVR) has demonstrated favourable effects on long-term prognosis, while the impact of adding percutaneous coronary intervention (PCI) to TAVR may depend on the CAD complexity and the feasibility of achieving complete or reasonably incomplete revascularization. Furthermore, the comparison between SAVR+CABG and TAVR+PCI in low-intermediate surgical risk and low-intermediate complex CAD patients did not reveal differences in all-cause mortality or stroke between the groups. However, there is some evidence showing a lower incidence of major cardiovascular events with the SAVR+CABG strategy for patients with complex CAD. Thus, SAVR+CABG seems to be the best option for patients with low-intermediate surgical risk and complex CAD, and TAVR+PCI for high surgical risk patients seeking complete and/or reasonable incomplete revascularization. After deciding between TAVR+PCI or SAVR+CABG, factors such as timing for PCI, low ejection fraction, coronary reaccess, and valve durability must be considered. Finally, alternative methods for assessing CAD severity are currently under evaluation to ascertain their real value for guiding revascularization in patients with severe AS with CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
3.
Rev. esp. cardiol. (Ed. impr.) ; 76(12): 991-1002, Dic. 2023. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-228116

RESUMO

Introducción y objetivos: Evaluar la prevalencia, las características clínicas y el impacto de la angina en pacientes con estenosis aórtica sometidos a implante percutáneo de válvula aórtica (TAVI). Métodos: Se analizó a 1.687 pacientes consecutivos con estenosis aórtica sometidos a TAVI, clasificados en función de la presencia o ausencia basal de angina. Los datos basales, del procedimiento y del seguimiento se recogieron en una base de datos local. Resultados: Un total de 497 pacientes (29%) presentaban angina antes del TAVI. Los pacientes con angina basal presentaban peor clase funcional (NYHA> II, el 69% frente al 63%; p=0,017) y una mayor prevalencia de enfermedad coronaria (el 74% frente al 56%; p <0,001). La angina basal no mostró impacto pronóstico a 1 año en mortalidad por cualquier causa (HR=1,02; IC95%, 0,71-1,48; p=0,898) ni en mortalidad cardiovascular (HR=1,2; IC95%, 0,69-2,11; p=0,517). Sin embargo, la persistencia de angina 30 días después del procedimiento se asoció con un incremento en la mortalidad a 1 año, tanto total (HR=4,86; IC95%, 1,71-13,8; p=0,003) como de causa cardiovascular (HR=20,7; IC95%, 3,50-122,6; p=0,001). Conclusiones: Más de un cuarto de los pacientes con estenosis aórtica sometidos a TAVI tenían angina antes del procedimiento. La angina basal no mostró impacto pronóstico alguno. Sin embargo, la persistencia de angina 30 días después del procedimiento se asoció con una mayor mortalidad al año.(AU)


Introduction and objectives: To evaluate the prevalence, clinical characteristics, and outcomes of patients with angina undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. Methods: A total of 1687 consecutive patients with severe aortic stenosis undergoing TAVR at our center were included and classified according to patient-reported angina symptoms prior to the TAVR procedure. Baseline, procedural and follow-up data were collected in a dedicated database. Results: A total of 497 patients (29%) had angina prior to the TAVR procedure. Patients with angina at baseline showed a worse New York Heart Association (NYHA) functional class (NYHA class> II: 69% vs 63%; P=.017), a higher rate of coronary artery disease (74% vs 56%; P <.001), and a lower rate of complete revascularization (70% vs 79%; P <.001). Angina at baseline had no impact on all-cause mortality (HR, 1.02; 95%CI, 0.71-1.48; P=.898) and cardiovascular mortality (HR, 1.2; 95%CI, 0.69-2.11; P=.517) at 1 year. However, persistent angina at 30 days post-TAVR was associated with increased all-cause mortality (HR, 4.86; 95%CI, 1.71-13.8; P=.003) and cardiovascular mortality (HR, 20.7; 95%CI, 3.50-122.6; P=.001) at 1-year follow-up. Conclusions: More than one-fourth of patients with severe aortic stenosis undergoing TAVR had angina prior to the procedure. Angina at baseline did not appear to be a sign of a more advanced valvular disease and had no prognostic impact; however, persistent angina at 30 days post-TAVR was associated with worse clinical outcomes.(AU)


Assuntos
Humanos , Masculino , Feminino , Angina Pectoris , Estenose da Valva Aórtica/complicações , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Doenças Cardiovasculares , Doença das Coronárias , Prevalência
4.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38000627

RESUMO

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

5.
JACC Cardiovasc Interv ; 16(24): 2999-3012, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37902146

RESUMO

BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. OBJECTIVES: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR. RESULTS: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found. CONCLUSIONS: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese
6.
Expert Rev Cardiovasc Ther ; 21(11): 747-761, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37869793

RESUMO

INTRODUCTION: Small aortic annulus (SAA) poses a challenge in the management of patients with severe aortic stenosis requiring aortic valve replacement - both surgical and transcatheter - since it has been associated with worse clinical outcomes. AREAS COVERED: This review aims to comprehensively summarize the available evidence regarding the management of aortic stenosis in patients with SAA and discuss the current controversies as well as future perspectives in this field. EXPERT OPINION: It is paramount to agree in a common definition for diagnosing and properly treating SAA patients, and for that purpose, multidetector computer tomography is essential. The results of recent trials led to the expansion of transcatheter aortic valve replacement among patients of all the surgical-risk spectrum, and the choice of treatment (transcatheter, surgical) should be based on patient comorbidities, anatomical characteristics, and patient preferences.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Desenho de Prótese
7.
JACC Cardiovasc Interv ; 16(18): 2262-2274, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37676226

RESUMO

BACKGROUND: The updated Valve Academic Research Consortium (VARC) definition for bleeding events after transcatheter aortic valve replacement (TAVR) lacks of clinical validation. OBJECTIVES: The aim of this study was to determine the incidence, predictors, and clinical impact of bleeding events following TAVR as defined by recent VARC-3 criteria. METHODS: A total of 2,384 consecutive patients with severe symptomatic aortic stenosis undergoing TAVR were included. Early (at index hospitalization) and late (after hospital discharge) bleeding complications were defined according to VARC-3 criteria as type 1, 2, 3, or 4. Baseline, procedural, and follow-up (24 [IQR: 12-43] months) data were prospectively collected. RESULTS: Bleeding events occurred in 761 patients (31.9%): types 1, 2, 3, and 4 in 169 (22.2%), 399 (52.4%), 149 (19.6%), and 44 (5.8%) patients, respectively. The primary vascular access site and gastrointestinal locations were the most common bleeding sources among early and late bleeding events, respectively. Female sex, thoracotomy access, larger (14-F) sheath use, and dual antiplatelet therapy determined an increased risk of early bleeding events (P < 0.02 for all). The use of the radial artery for secondary access was associated with a significant risk reduction of early bleeding (P < 0.001). Type 2 and type 3 events were associated with an increased mortality risk at 30-day (HR: 2.94 [95% CI: 1.43-6.03; P = 0.003] and HR: 4.91 [95% CI: 2.19-11.03; P < 0.001], respectively) and 1-year (HR: 1.86 [95% CI: 1.28-2.69; P = 0.001] and HR: 2.28 [95% CI: 1.41-3.66; P = 0.001], respectively) follow-up. A similar prognostic pattern was observed when applying VARC-2 criteria but with a much lower global incidence of early bleeding events (19% vs 27%; P < 0.001). CONCLUSIONS: Bleeding events after TAVR were associated with poorer short- and long-term survival. The magnitude of this correlation was proportional to bleeding severity defined according to VARC-3 criteria. Further studies on bleeding prevention following TAVR are warranted to improve procedural safety and patient prognosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Prognóstico , Incidência , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Medição de Risco , Hemorragia/epidemiologia , Hemorragia/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
8.
Am J Cardiol ; 205: 28-34, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37579657

RESUMO

Assessment of frailty before heart transplant (HT) is recommended but is not standard in most HT protocols. Our objective was to evaluate frailty at inclusion in HT list and during follow-up and to assess the influence of baseline frailty on prognosis. A prospective multicenter study in all adults included in the nonurgent HT waiting list. Frailty was defined as Fried's frailty phenotype score ≥3. Mean follow-up was 25.9 ± 1.2 months. Of 99 patients (mean age 54.8 [43.1 to 62.5] years, 70 men [70.7%]), 28 were frail (28.3%). A total of 85 patients received HT after 0.5 ± 0.01 years. Waiting time was shorter in frail patients (0.6 years [0.3 to 0.8] vs 0.2 years [0.1 to 0.4], p = 0.001) because of an increase in priority. Baseline frailty was not associated with overall mortality, (hazard ratio 0.99 [95% confidence interval 0.41 to 2.37, p = 0.98]). A total of 16 transplant recipients died (18.8%). Of the remaining 69 HT recipients, 65 underwent frailty evaluation during follow-up. Patients without baseline frailty (n = 49) did not develop it after HT. Of 16 patients with baseline frailty, only 2 were still frail at the end of follow-up. Frailty is common in HT candidates but is reversible in most cases after HT and is not associated with post-transplant mortality. Our results suggest that frailty should not be considered an exclusion criterion for HT.


Assuntos
Fragilidade , Transplante de Coração , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Fragilidade/epidemiologia , Modelos de Riscos Proporcionais , Listas de Espera
9.
Rev Esp Cardiol (Engl Ed) ; 76(12): 991-1002, 2023 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37137426

RESUMO

INTRODUCTION AND OBJECTIVES: To evaluate the prevalence, clinical characteristics, and outcomes of patients with angina undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. METHODS: A total of 1687 consecutive patients with severe aortic stenosis undergoing TAVR at our center were included and classified according to patient-reported angina symptoms prior to the TAVR procedure. Baseline, procedural and follow-up data were collected in a dedicated database. RESULTS: A total of 497 patients (29%) had angina prior to the TAVR procedure. Patients with angina at baseline showed a worse New York Heart Association (NYHA) functional class (NYHA class> II: 69% vs 63%; P=.017), a higher rate of coronary artery disease (74% vs 56%; P <.001), and a lower rate of complete revascularization (70% vs 79%; P <.001). Angina at baseline had no impact on all-cause mortality (HR, 1.02; 95%CI, 0.71-1.48; P=.898) and cardiovascular mortality (HR, 1.2; 95%CI, 0.69-2.11; P=.517) at 1 year. However, persistent angina at 30 days post-TAVR was associated with increased all-cause mortality (HR, 4.86; 95%CI, 1.71-13.8; P=.003) and cardiovascular mortality (HR, 20.7; 95%CI, 3.50-122.6; P=.001) at 1-year follow-up. CONCLUSIONS: More than one-fourth of patients with severe aortic stenosis undergoing TAVR had angina prior to the procedure. Angina at baseline did not appear to be a sign of a more advanced valvular disease and had no prognostic impact; however, persistent angina at 30 days post-TAVR was associated with worse clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Prognóstico , Angina Pectoris/epidemiologia , Angina Pectoris/etiologia , Angina Pectoris/cirurgia , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
10.
JACC Cardiovasc Interv ; 16(10): 1221-1232, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225294

RESUMO

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for myocardial injury after transcatheter aortic valve replacement (TAVR) lacks of clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of periprocedural myocardial injury (PPMI) following TAVR as defined by recent VARC-3 criteria. METHODS: We included 1,394 consecutive patients who underwent TAVR with a new-generation transcatheter heart valve. High-sensitivity troponin levels were assessed at baseline and within 24 hours after the procedure. PPMI was defined according to VARC-3 criteria as an increase ≥70 times in troponin levels (vs ≥15 times according to the VARC-2 definition). Baseline, procedural, and follow-up data were prospectively collected. RESULTS: PPMI was diagnosed in 193 (14.0%) patients. Female sex and peripheral artery disease were independent predictors of PPMI (P < 0.01 for both). PPMI was associated with a higher risk of mortality at 30-day (HR: 2.69, 95% CI: 1.50-4.82; P = 0.001) and 1-year (for all-cause mortality, HR: 1.54; 95% CI: 1.04-2.27; P = 0.032; for cardiovascular mortality, HR: 3.04; 95% CI: 1.68-5.50; P < 0.001) follow-up. PPMI according to VARC-2 criteria had no impact on mortality. CONCLUSIONS: About 1 out of 10 patients undergoing TAVR in the contemporary era had PPMI as defined by recent VARC-3 criteria, and baseline factors like female sex and peripheral artery disease determined an increased risk. PPMI had a negative impact on early and late survival. Further studies on the prevention of PPMI post-TAVR and implementing measures to improve outcomes in PPMI patients are warranted.


Assuntos
Traumatismos Cardíacos , Doença Arterial Periférica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Cateteres , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia
12.
Can J Cardiol ; 39(7): 901-908, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36806689

RESUMO

BACKGROUND: No data exist on the clinical and prognostic significance of syncope in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. METHODS: A total of 1705 consecutive patients with severe aortic stenosis undergoing TAVR in a tertiary university centre between 2007 and 2021 were included and classified according to the presence of syncope before the TAVR procedure. Baseline, procedural, and follow-up data were collected prospectively in a dedicated database. RESULTS: A total of 115 patients (7%) presented with syncope before the TAVR procedure. Of these, 15 patients (13%) showed arrhythmic episodes as the probable cause of the syncope, and all of them had pacemakers implanted at a median of 13 (6 to 53) days before the TAVR procedure. Patients with syncope were older (82 ± 8 years vs 80 ± 8 years, P = 0.001) and had a higher rate of pacemaker implantation before the TAVR procedure (27% vs 14%, P < 0.001), with no differences between groups regarding the severity of aortic stenosis (transvalvular gradient, valve area). There were no differences between groups in 30-day (adjusted hazard ratio [HR], 1.28; 95% confidence interval [CI], 0.46-3.60) and 1-year (adjusted HR, 0.71; 95% CI, 0.0.35-1.45) mortality following TAVR. CONCLUSIONS: Syncope was not associated with a more advanced valvular disease and had no significant prognostic impact on patients undergoing TAVR. However, arrhythmias and conduction-system disturbances were more common in patients with previous syncope and might play a relevant role in the pathogenesis of syncope in patients with aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Fatores de Risco , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Prognóstico , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
13.
J Am Coll Cardiol ; 81(7): 684-702, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36792284

RESUMO

Transcatheter aortic valve replacement (TAVR) has gained over time a major reduction in procedural complications. Despite this, clinically relevant bleeding still occurs in a non-negligible proportion of patients and adversely affects prognosis. Patients with severe aortic stenosis are at heightened risk for spontaneous bleeding due to advanced age and a high comorbidity burden. Also, procedural factors and antithrombotic management contribute to define individual bleeding susceptibility. Bleeding prevention represents an emerging area for improving patient care. Because of the tight hemorrhagic/ischemic balance, a tailored approach based on individual bleeding-risk profile, such as a less invasive antithrombotic regimen or appropriate diagnostic preprocedural evaluation, should be pursued to avoid bleeding events. This review aims to provide an in-depth overview of bleeding events in the TAVR field, including definitions, timing and the extent of risk, and clinical impact, as well as updates on antithrombotic management and its potential influence on bleeding complications.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fibrinolíticos/uso terapêutico , Fatores de Risco , Resultado do Tratamento , Hemorragia/epidemiologia , Hemorragia/etiologia , Hemorragia/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/tratamento farmacológico , Valva Aórtica/cirurgia
16.
Eur J Heart Fail ; 25(3): 373-385, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36404400

RESUMO

AIMS: Pulmonary hypertension (PH) associated with left heart disease is an increasingly prevalent problem, orphan of targeted therapies, and related to a poor prognosis, particularly when pre- and post-capillary PH combine. The current study aimed to determine whether treatment with the selective ß3 adrenoreceptor agonist mirabegron improves outcomes in patients with combined pre- and post-capillary PH (CpcPH). METHODS AND RESULTS: The ß3 Adrenergic Agonist Treatment in Chronic Pulmonary Hypertension Secondary to Heart Failure (SPHERE-HF) trial is a multicentre, randomized, parallel, placebo-controlled clinical trial that enrolled stable patients with CpcPH associated with symptomatic heart failure. A total of 80 patients were assigned to receive mirabegron (50 mg daily, titrated till 200 mg daily, n = 39) or placebo (n = 41) for 16 weeks. Of them, 66 patients successfully completed the study protocol and were valid for the main analysis. The primary endpoint was the change in pulmonary vascular resistance (PVR) on right heart catheterization. Secondary outcomes included the change in right ventricular (RV) ejection fraction by cardiac magnetic resonance or computed tomography, other haemodynamic variables, functional class, and quality of life. The trial was negative for the primary outcome (placebo-corrected mean difference of 0.62 Wood units, 95% confidence interval [CI] -0.38, 1.61, p = 0.218). Patients receiving mirabegron presented a significant improvement in RV ejection fraction as compared to placebo (placebo-corrected mean difference of 3.0%, 95% CI 0.4, 5.7%, p = 0.026), without significant differences in other pre-specified secondary outcomes. CONCLUSIONS: SPHERE-HF is the first clinical trial to assess the potential benefit of ß3 adrenergic agonists in PH. The trial was negative since mirabegron did not reduce PVR, the primary endpoint, in patients with CpcPH. On pre-specified secondary outcomes, a significant improvement in RV ejection fraction assessed by advanced cardiac imaging was found, without differences in functional class or quality of life.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Humanos , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/etiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/tratamento farmacológico , Qualidade de Vida , Volume Sistólico , Agonistas Adrenérgicos/uso terapêutico , Método Duplo-Cego , Resultado do Tratamento
17.
Methods Protoc ; 5(5)2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-36287047

RESUMO

INTRODUCTION: Heart transplant (HT) survival has barely improved in the last decades, which is unsatisfactory for many HT recipients. The development of anti-human leukocyte antigen (anti-HLA) antibodies in HT patients is associated with a cardiac allograft dysfunction. The mechanisms leading to this damage are unclear. The Multimodality Evaluation Of Antibody-Mediated Injury In Heart Transplantation (LEONE-HT) study aimed to thoroughly describe the damage inflicted on the myocardium by anti-HLA antibodies. METHODS AND ANALYSIS: The LEONE-HT study is a cohort study with a cross-sectional approach in which HT patients with positive anti-HLA antibodies are compared with coetaneous HT patients with negative anti-HLA antibodies. All patients will undergo a state-of-the-art multimodal assessment, including imaging techniques, coronary anatomy and physiology evaluations and histological and immunological analyses. The individual and combined primary outcomes of structural graft injuries and longitudinal secondary outcomes are to be compared between the exposed and non-exposed groups with univariate and multivariable descriptive analyses. ETHICS AND DISSEMINATION: The LEONE-HT study is carried out in accordance with the principles set out in the Declaration of Helsinki and the International Conference on Harmonization guidelines for good clinical practice and following national laws and regulations. The study design, objectives and participant centers have been communicated to clinicaltrials.gov (NCT05184426). The LEONE-HT study counts on the support of patient associations to disseminate the objectives and results of the research. This study was funded by the Spanish Ministry of Science and Innovation and the Spanish Society of Cardiology.

18.
J Stroke ; 24(3): 335-344, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36221936

RESUMO

Transcatheter patent foramen ovale (PFO) closure is a safe and effective treatment for secondary prevention after a PFO-associated stroke as demonstrated in multiple large randomized clinical trials. However, these trials excluded a significant proportion of patients who could have benefited from percutaneous PFO closure due to coexisting potential confounders such as additional thromboembolic risk factors, namely thrombophilia. Since scarce and conflicting data existed on such patients, current clinical management guidelines on patients with PFO mainly recommended against PFO closure in patients with thrombophilia and failed to provide any recommendation on the type and duration of antithrombotic treatment after transcatheter PFO closure. In the past 2 years, there has been new evidence supporting transcatheter PFO closure as a clinically meaningful alternative (vs. medical treatment) in this high-risk group of patients, along with additional data supporting the important role of systematic screening for thrombophilia in PFO-associated cerebrovascular events. This review article provides an updated overview of the incidence, clinical characteristics and outcomes of PFO closure in patients with thrombophilia, also commenting on the most appropriate medical treatment after PFO closure and future perspectives in the field.

19.
Heart Rhythm ; 19(11): 1890-1898, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35952981

RESUMO

Transcatheter aortic valve replacement (TAVR) is well established for treating severe symptomatic aortic stenosis. Whereas broad information on the epidemiology, clinical implications, and management of bradyarrhythmias after TAVR is available, data about tachyarrhythmic events remain scarce. Despite the progressively lower risk profile of TAVR patients and the improvement in device characteristics and operator skills, approximately 10% of patients develop new-onset atrial fibrillation (NOAF) after TAVR. The proportion of patients in whom NOAF actually corresponds to previously undiagnosed silent atrial fibrillation (AF) has not been properly determined. The transapical approach, the need for pre- or post- balloon dilation, and the presence of periprocedural complications have been associated with a higher risk of NOAF. Older age, left atrial volume, or worse functional class are patient-derived risk factors shared with preprocedural AF. NOAF after TAVR has been associated with poorer survival and a higher incidence of cerebrovascular events. However, patient management differs markedly among different centers, especially with regard to anticoagulation in patients with short-duration AF episodes detected in the periprocedural setting and in cases of silent NOAF detected during continuous electrocardiographic (ECG) monitoring. Evidence about ventricular arrhythmias is even more scarce than for AF. Some case reports of sudden cardiac death after TAVR in patients with a pacemaker have identified ventricular tachycardia or ventricular fibrillation in device interrogation. TAVR has been shown to reduce the arrhythmic burden, but a significant proportion of patients (16%) present with complex premature ventricular complex arrhythmias within the year after TAVR. Whether these events are related to poorer outcomes is unknown. Continuous ECG monitoring after TAVR may help describe the frequency, risk factors, and prognostic implications of tachyarrhythmias in this population.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Incidência , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Taquicardia/etiologia , Valva Aórtica/cirurgia
20.
Expert Rev Med Devices ; 19(7): 561-569, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36005274

RESUMO

INTRODUCTION: Since the initial experience with the CoreValve (Medtronic, Minneapolis, Minnesota), there have been continuous iterations of this valve system in order to improve procedural success and reduce periprocedural complications. The Evolut Pro, Pro+, and FX are the latest generations of this transcatheter heart valve (THV). AREAS COVERED: This review paper aims to analyze the main characteristics and clinical evidence about the Evolut Pro THV and summarize the main iterations of the newer generation Evolut FX valve system. EXPERT OPINION: The Evolut Pro system has been associated with good clinical outcomes and excellent valve hemodynamic performance including reduced rates of paravalvular leaks. Technical enhancements to improve valve positioning, orientation, and vascular access have been implemented in the newer generation Evolut FX system.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...